How to Set the Fractional Power Control Compensation Factor in LTE ?

Abstract : The uplink power control procedure in Long Term Evolution (LTE) cellular networks is made of an open-loop part and a closed loop part. In this paper, we focus on the former and study the compensation factor of the related Fractional Power Control (FPC) scheme. In particular, we propose a first analytical approach in order to derive approximate equations for the Signal to Interference plus Noise Ratio (SINR) at a given distance of the eNode-B, the average SINR, and the average cell spectral efficiency. This method avoids extensive and timeconsuming simulations. From derived expressions, we are able to find the optimal compensation factor, and to study the impact of various network and environment parameters on the system performance.